Share:

SR-276 over TRACHYTE WASH

Map

Coordinates:
+37.95825, -110.57708
37°57'30" N, 110°34'37" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR-276 over TRACHYTE WASH
Structure number:0C 524
Location:5 MI.SO.OF TRACHYTE JCT.
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:89.9 ft. [27.4 m]
Total length:183.7 ft. [56.0 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:34.1 ft. [10.4 m]
Owner:State Highway Agency [01]
Year built:1967
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:260 [as of 2014]
Truck traffic:26% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:89.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018FairSatisfactorySatisfactorySatisfactory26089.6
October 2016FairGoodSatisfactorySatisfactory26090.6
October 2014FairGoodSatisfactorySatisfactory24290.4
October 2012FairGoodSatisfactorySatisfactory24289.7
March 2011FairGoodSatisfactorySatisfactory54085.9
December 2008FairGoodSatisfactorySatisfactory54085.9
May 2007FairGoodGoodSatisfactory37588.5
March 2005FairGoodGoodSatisfactory37588.5
November 2002FairGoodGoodSatisfactory93073.9
October 2000FairGoodGoodSatisfactory87068.9
September 1998FairGoodGoodSatisfactory87068.9
October 1996FairGoodGoodSatisfactory70080.0
November 1994FairGoodGoodSatisfactory70086.7
April 1993FairGoodGoodSatisfactory61586.4
October 1990FairGoodVery GoodSatisfactory60586.5

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.7226477500
Deck
Reinforced Concrete Decksq. ft.6,2805,296950340
Substructure
Reinforced Concrete Pier Walllinear ft.1010000
Reinforced Concrete Abutmentlinear ft.69353400
Reinforced Concrete Pier Caplinear ft.3434000
Joints
Compression Jointlinear ft.6600660
Bearings
Movable Bearingeach80800
Fixed Bearingeach40400
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.4040394100