Old Stage Road over NS Railway
Map
Coordinates:
+37.54164, -79.0759237°32'30" N, 79°04'33" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | Old Stage Road over NS Railway |
Structure number: | 000000000001508 |
Location: | 0.77-Rt 786/1.02-Rt 624 |
Purpose: | Carries highway over railroad |
Route classification: | Local (Rural) [09] |
Length of largest span: | 74.2 ft. [22.6 m] |
Total length: | 205.1 ft. [62.5 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 28.5 ft. [8.7 m] |
Vertical clearance below bridge: | 23.0 ft. [7.0 m] |
Skew angle: | 38° |
Owner: | State Highway Agency [01] |
Year built: | 1964 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 13.5 / HS 15 [3] |
Number of main spans: | 3 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: May 2018
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 174 [as of 2014] |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Underclearances appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 83.5 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $1,091,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2018 | Poor | Poor | Satisfactory | Satisfactory | 174 | 83.5 |
May 2016 | Fair | Fair | Satisfactory | Satisfactory | 174 | 85.5 |
May 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 160 | 86.5 |
May 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 162 | 86.5 |
May 2010 | Fair | Satisfactory | Good | Satisfactory | 162 | 85.7 |
May 2008 | Fair | Satisfactory | Good | Satisfactory | 162 | 88.7 |
May 2006 | Fair | Satisfactory | Good | Good | 181 | 86.7 |
July 2004 | Fair | Satisfactory | Good | Good | 181 | 86.7 |
July 2002 | Fair | Satisfactory | Good | Good | 181 | 86.7 |
September 2000 | Fair | Satisfactory | Good | Good | 318 | 82.1 |
November 1998 | Fair | Satisfactory | Very Good | Good | 318 | 82.1 |
July 1996 | Fair | Satisfactory | Very Good | Good | 318 | 82.1 |
June 1994 | Good | Good | Very Good | Very Good | 318 | 81.1 |
November 1991 | Good | Good | Very Good | Very Good | 241 | 86.9 |