Old Furnace Rd/703 over Sinking Creek
Map
Coordinates:
+37.30737, -80.4682437°18'27" N, 80°28'06" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | Old Furnace Rd/703 over Sinking Creek |
Structure number: | 000000000008481 |
Location: | 0.42-RT 42;0.06- DEAD END |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 3.0 ft. [0.9 m] |
Total length: | 64.0 ft. [19.5 m] |
Roadway width between curbs: | 11.2 ft. [3.4 m] |
Deck width edge-to-edge: | 12.1 ft. [3.7 m] |
Owner: | State Highway Agency [01] |
Year built: | 1932 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 20 |
Main spans material: | Steel [3] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 50 [as of 2014] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Culvert condition: | Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 58.2 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $237,000 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
August 2017 | Fair | 5 out of 10 | 50 | 58.2 |
August 2015 | Fair | 5 out of 10 | 50 | 58.2 |
August 2013 | Fair | 5 out of 10 | 43 | 58.3 |
August 2011 | Fair | 5 out of 10 | 43 | 58.3 |
August 2009 | Fair | 5 out of 10 | 43 | 58.3 |
August 2007 | Fair | 5 out of 10 | 6 | 61.9 |
August 2005 | Fair | 5 out of 10 | 6 | 61.9 |
August 2003 | Fair | 5 out of 10 | 6 | 61.9 |
August 2001 | Fair | 5 out of 10 | 14 | 61.8 |
September 1999 | Fair | 5 out of 10 | 14 | 61.8 |
August 1997 | Good | N out of 10 | 33 | 69.6 |
August 1995 | Good | N out of 10 | 33 | 69.7 |
August 1994 | Good | N out of 10 | 33 | 69.7 |
August 1993 | Good | N out of 10 | 11 | 69.9 |
August 1992 | Good | N out of 10 | 11 | 69.3 |
August 1990 | Good | N out of 10 | 11 | 74.4 |