Share:

WBL ROUTE 0064 over RTE 154(DURANT RD) & CSX

Map

Coordinates:
+37.77342, -79.99314
37°46'24" N, 79°59'35" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WBL ROUTE 0064 over RTE 154(DURANT RD) & CSX
Structure number:000000000020159
Location:.35 W A CL & 1.05 E A CL
Purpose:Carries highway over highway and railroad
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:94.2 ft. [28.7 m]
Total length:253.0 ft. [77.1 m]
Roadway width between curbs:43.6 ft. [13.3 m]
Deck width edge-to-edge:46.9 ft. [14.3 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1964
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:4
Main spans material:Steel [3]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:5,670 [as of 2014]
Truck traffic:22% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:96.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2017FairSatisfactorySatisfactorySatisfactory567096.5
November 2015FairSatisfactoryGoodSatisfactory567096.5
November 2013FairSatisfactoryGoodSatisfactory673695.4
November 2011GoodGoodGoodGood673695.4
November 2009GoodGoodGoodGood673697.4
October 2007GoodGoodGoodGood653897.4
September 2005GoodGoodGoodGood771498.0
September 2003GoodGoodGoodGood733598.0
October 2001GoodGoodGoodGood746498.0
October 1999FairGoodSatisfactoryGood1147598.0
September 1997FairGoodSatisfactoryGood1147598.0
October 1995FairGoodSatisfactoryGood1147593.0
September 1993FairSatisfactorySatisfactorySatisfactory1147592.2
September 1991FairSatisfactorySatisfactorySatisfactory1147592.2
September 1989FairSatisfactorySatisfactorySatisfactory1147591.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1,7711,65311620
Steel Protective Coatingsq. ft.1,232001,2320
Deck
Reinforced Concrete Decksq. ft.11,86811,195616570
Wearing Surfacessq. ft.10,19410,1425200
Substructure
Reinforced Concrete Columneach94500
Reinforced Concrete Abutmentlinear ft.1165223410
Reinforced Concrete Pier Caplinear ft.5604790
Joints
Compression Jointlinear ft.230023000
Bearings
Movable Bearingeach2801990
Steel Protective Coatingsq. ft.112560560
Fixed Bearingeach2802800
Steel Protective Coatingsq. ft.112560560
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.506505010
Reinforced Concrete Bridge Raillinear ft.50632018600