SR 164 WBL over Commonwealth RR
Map
Coordinates:
+36.87215, -76.3704936°52'20" N, 76°22'14" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 164 WBL over Commonwealth RR |
Structure number: | 000000000021206 |
Location: | 0.45MIFR.CEDARLN/1.2 WNR |
Purpose: | Carries highway over railroad |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 184.1 ft. [56.1 m] |
Total length: | 337.6 ft. [102.9 m] |
Roadway width between curbs: | 38.4 ft. [11.7 m] |
Deck width edge-to-edge: | 42.0 ft. [12.8 m] |
Vertical clearance below bridge: | 19.7 ft. [6.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1991 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 2 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: July 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 22,735 [as of 2014] |
Truck traffic: | 5% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Underclearances appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 80.4 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2018 | Fair | Satisfactory | Fair | Satisfactory | 22735 | 80.4 |
July 2016 | Fair | Satisfactory | Fair | Satisfactory | 22735 | 80.4 |
July 2014 | Fair | Satisfactory | Fair | Satisfactory | 22276 | 83.0 |
July 2012 | Fair | Satisfactory | Fair | Satisfactory | 22276 | 84.0 |
July 2010 | Fair | Good | Fair | Satisfactory | 22276 | 84.0 |
June 2009 | Fair | Fair | Satisfactory | Satisfactory | 22276 | 94.0 |
September 2008 | Fair | Fair | Satisfactory | Satisfactory | 22041 | 94.0 |
August 2007 | Fair | Fair | Satisfactory | Fair | 16799 | 83.0 |
July 2006 | Fair | Fair | Satisfactory | Fair | 13678 | 83.0 |
August 2005 | Fair | Fair | Good | Fair | 11337 | 83.0 |
August 2004 | Fair | Fair | Good | Fair | 11229 | 83.0 |
July 2003 | Fair | Satisfactory | Good | Satisfactory | 14012 | 95.0 |
July 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 13405 | 95.0 |
October 1999 | Fair | Satisfactory | Satisfactory | Satisfactory | 9772 | 95.0 |
August 1998 | Fair | Satisfactory | Satisfactory | Good | 9772 | 95.0 |
July 1997 | Fair | Satisfactory | Satisfactory | Good | 23000 | 95.0 |
May 1995 | Fair | Satisfactory | Satisfactory | Good | 1200 | 95.0 |
July 1993 | Good | Good | Good | Good | 1200 | 95.0 |
June 1991 | Good | Excellent | Excellent | Excellent | 1200 | 95.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Closed Web/Box Girder | linear ft. | 113 | 85 | 16 | 12 | 0 |
Steel Protective Coating | sq. ft. | 3,051 | 1,513 | 1,526 | 12 | 0 |
Steel Girder/Beam | linear ft. | 1,962 | 1,936 | 26 | 0 | 0 |
Steel Protective Coating | sq. ft. | 6,625 | 6,620 | 0 | 0 | 5 |
Deck |
Reinforced Concrete Deck | sq. ft. | 14,108 | 10,091 | 6 | 4,011 | 0 |
Substructure |
Reinforced Concrete Column | each | 2 | 1 | 0 | 1 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 17 | 11 | 5 | 1 | 0 |
Reinforced Concrete Abutment | linear ft. | 206 | 38 | 13 | 155 | 0 |
Joints |
Strip Seal Joint | linear ft. | 84 | 0 | 0 | 0 | 84 |
Bearings |
Pot Bearing | each | 10 | 2 | 0 | 8 | 0 |
Steel Protective Coating | sq. ft. | 10 | 0 | 0 | 3 | 7 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 675 | 346 | 0 | 329 | 0 |