ROY L. WEBRHWY/220 over RT220 BUS & FRANKLIN RD
Map
Coordinates:
+37.25822, -79.9473137°15'30" N, 79°56'50" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | ROY L. WEBRHWY/220 over RT220 BUS & FRANKLIN RD |
Structure number: | 000000000021711 |
Location: | 0.90-RTE24E; 2.64-RTE419 |
Purpose: | Carries highway over highway |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 81.0 ft. [24.7 m] |
Total length: | 202.4 ft. [61.7 m] |
Roadway width between curbs: | 91.9 ft. [28.0 m] |
Deck width edge-to-edge: | 98.1 ft. [29.9 m] |
Vertical clearance below bridge: | 16.4 ft. [5.0 m] |
Skew angle: | 21° |
Owner: | State Highway Agency [01] |
Year built: | 1973 |
Year reconstructed: | 1995 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 4 |
Main spans material: | Steel [3] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: November 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 70,741 [as of 2014] |
Truck traffic: | 12% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 77.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $19,477,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
November 2017 | Fair | Satisfactory | Satisfactory | Fair | 70741 | 77.0 |
November 2015 | Fair | Satisfactory | Satisfactory | Fair | 70741 | 77.0 |
November 2013 | Fair | Good | Satisfactory | Fair | 57947 | 78.4 |
November 2011 | Fair | Good | Satisfactory | Fair | 57947 | 78.4 |
November 2009 | Fair | Good | Satisfactory | Fair | 57947 | 78.4 |
December 2007 | Fair | Good | Satisfactory | Fair | 65081 | 77.6 |
November 2005 | Fair | Good | Satisfactory | Fair | 64782 | 77.6 |
December 2003 | Fair | Good | Satisfactory | Fair | 66474 | 77.4 |
November 2001 | Fair | Good | Satisfactory | Fair | 61283 | 78.0 |
December 1999 | Fair | Good | Satisfactory | Fair | 52000 | 77.1 |
January 1998 | Fair | Good | Satisfactory | Fair | 64000 | 75.7 |
November 1995 | Fair | Good | Satisfactory | Fair | 56330 | 77.9 |
November 1993 | Fair | Good | Satisfactory | Fair | 56330 | 77.9 |
November 1991 | - | - | - | - | 56330 | 89.6 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 2,451 | 2,196 | 250 | 5 | 0 |
Steel Protective Coating | sq. ft. | 20,510 | 0 | 18,360 | 2,100 | 50 |
Deck |
Reinforced Concrete Deck | sq. ft. | 19,845 | 19,712 | 123 | 10 | 0 |
Wearing Surfaces | sq. ft. | 18,614 | 18,409 | 205 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 18 | 10 | 8 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 210 | 188 | 22 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 308 | 51 | 257 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 710 | 710 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 48 | 24 | 24 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Fixed Bearing | each | 48 | 24 | 24 | 0 | 0 |
Steel Protective Coating | sq. ft. | 10,753 | 10,753 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 390 | 389 | 0 | 1 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 602 | 526 | 75 | 1 | 0 |