Roy Weber Exp 220N over NSRR;Albml Ave & Wmsn Rd
Map
Coordinates:
+37.26255, -79.9393037°15'45" N, 79°56'21" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | Roy Weber Exp 220N over NSRR;Albml Ave & Wmsn Rd |
Structure number: | 000000000021715 |
Location: | 0.26 Rt24 & 2.54-Roa CL. |
Purpose: | Carries highway over highway and railroad |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 98.1 ft. [29.9 m] |
Total length: | 394.0 ft. [120.1 m] |
Roadway width between curbs: | 46.9 ft. [14.3 m] |
Deck width edge-to-edge: | 50.9 ft. [15.5 m] |
Vertical clearance below bridge: | 23.0 ft. [7.0 m] |
Skew angle: | 59° |
Owner: | State Highway Agency [01] |
Year built: | 1974 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: October 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 32,500 [as of 2017] |
Truck traffic: | 13% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Basically intolerable requiring high priority of replacement [2] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 74.3 |
Recommended work: | Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31] |
Estimated cost of work: | $34,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
October 2018 | Fair | Satisfactory | Good | Fair | 32500 | 74.3 |
October 2017 | Fair | Satisfactory | Good | Fair | 35371 | 74.8 |
October 2016 | Fair | Satisfactory | Good | Fair | 35371 | 74.8 |
October 2015 | Fair | Satisfactory | Good | Fair | 35371 | 74.8 |
October 2013 | Fair | Satisfactory | Good | Fair | 28973 | 75.9 |
October 2012 | Fair | Satisfactory | Good | Fair | 28973 | 75.9 |
October 2011 | Fair | Satisfactory | Good | Fair | 28973 | 75.9 |
October 2010 | Fair | Satisfactory | Good | Fair | 28973 | 75.9 |
October 2009 | Fair | Satisfactory | Good | Fair | 28973 | 77.9 |
December 2008 | Fair | Satisfactory | Good | Fair | 31539 | 81.8 |
October 2007 | Fair | Satisfactory | Good | Fair | 32540 | 81.6 |
November 2006 | Fair | Satisfactory | Good | Fair | 32350 | 81.6 |
October 2005 | Fair | Satisfactory | Good | Fair | 32391 | 81.6 |
October 2003 | Fair | Satisfactory | Good | Fair | 33237 | 81.5 |
November 2002 | Fair | Satisfactory | Good | Fair | 30641 | 81.9 |
October 2001 | Fair | Satisfactory | Good | Fair | 30641 | 81.9 |
November 2000 | Fair | Satisfactory | Good | Fair | 26000 | 76.4 |
October 1999 | Fair | Satisfactory | Good | Fair | 26000 | 76.4 |
October 1997 | Fair | Satisfactory | Good | Fair | 32000 | 75.4 |
September 1996 | Fair | Good | Good | Fair | 30310 | 75.7 |
August 1995 | Fair | Good | Good | Fair | 30310 | 76.4 |
August 1993 | Fair | Satisfactory | Good | Satisfactory | 30310 | 88.2 |
August 1991 | Fair | Fair | Fair | Fair | 30310 | 75.3 |
August 1989 | Fair | Fair | Fair | Fair | 30310 | 75.3 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 2,329 | 2,329 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 20,666 | 20,666 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 21,455 | 21,207 | 230 | 18 | 0 |
Wearing Surfaces | sq. ft. | 18,479 | 17,863 | 608 | 8 | 0 |
Substructure |
Reinforced Concrete Column | each | 15 | 7 | 0 | 8 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 20 | 20 | 0 | 0 | 0 |
Steel Pier Cap | linear ft. | 50 | 48 | 0 | 2 | 0 |
Steel Protective Coating | sq. ft. | 1,545 | 1,541 | 0 | 0 | 4 |
Reinforced Concrete Pier Cap | linear ft. | 258 | 76 | 91 | 91 | 0 |
Joints |
Pourable Joint | linear ft. | 373 | 373 | 0 | 0 | 0 |
Bearings |
Elastomeric Bearing | each | 42 | 16 | 22 | 4 | 0 |
Steel Protective Coating | sq. ft. | 211 | 101 | 0 | 110 | 0 |
Fixed Bearing | each | 35 | 10 | 25 | 0 | 0 |
Steel Protective Coating | sq. ft. | 176 | 50 | 0 | 126 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 394 | 394 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 788 | 694 | 91 | 3 | 0 |