Share:

US 58 EBL Bypass over Halifax Street

Map

Coordinates:
+36.70466, -77.53358
36°42'17" N, 77°32'01" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 58 EBL Bypass over Halifax Street
Structure number:000000000023377
Location:0.10 fr 301/1.80 to 58 Bu
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:51.8 ft. [15.8 m]
Total length:118.1 ft. [36.0 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:63.3 ft. [19.3 m]
Vertical clearance below bridge:20.0 ft. [6.1 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1993
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:7,190 [as of 2014]
Truck traffic:28% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:58.5 tons [53.2 metric tons]
Inventory rating:45.1 tons [41.0 metric tons]
Sufficiency rating:97.3

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
October 201597.3FairGoodGoodSatisfactory-7190
October 201397.3FairGoodGoodSatisfactory-7171
October 201197.3GoodGoodVery GoodGood-7171
October 200997.3GoodGoodVery GoodGood-7171
October 200797.3GoodGoodVery GoodGood-7337
October 200597.4GoodGoodVery GoodGood-6939
October 200397.4GoodGoodVery GoodGood-6680
October 200197.4GoodGoodVery GoodGood-6500
November 199997.1GoodGoodVery GoodGood-9772
November 199797.2GoodGoodVery GoodGood-8500
November 199597.4GoodGoodVery GoodGood-7825
November 199397.4GoodVery GoodGoodGood-7825

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,2981,298000
Deck
Reinforced Concrete Decksq. ft.7,47407,47400
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.120120000
Reinforced Concrete Pier Caplinear ft.120120000
Joints
Compression Jointlinear ft.1271151200
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.236236000