Share:

SWEENEY BLVD over DRAINAGE DITCH

Map

Coordinates:
+37.07623, -76.35601
37°04'34" N, 76°21'22" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SWEENEY BLVD over DRAINAGE DITCH
Structure number:AFVAMUHJ11111
Location:0.1 MILES WEST OF NEALY A
Purpose:Carries highway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:265.8 ft. [81.0 m]
Total length:265.8 ft. [81.0 m]
Roadway width between curbs:39.0 ft. [11.9 m]
Deck width edge-to-edge:51.2 ft. [15.6 m]
Owner:Air Force [72]
Year built:1960
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:6
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Not applicable [N]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,500 [as of 2016]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:Navigation protection not required [1]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:69.4

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
November 2018Fair5 out of 10250069.4
November 2016Fair5 out of 10250073.2
July 2014Fair6 out of 10380095.8
July 2012Fair6 out of 10380095.8
July 2010Fair6 out of 10380095.8
May 2008Fair6 out of 10380095.8