C3004 over TROUT RIVER
Map
Coordinates:
+44.90724, -72.6556244°54'26" N, 72°39'20" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | C3004 over TROUT RIVER |
Structure number: | 100610003306101 |
Location: | @ JCT W VT118 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 65.9 ft. [20.1 m] |
Total length: | 85.0 ft. [25.9 m] |
Roadway width between curbs: | 13.5 ft. [4.1 m] |
Deck width edge-to-edge: | 15.4 ft. [4.7 m] |
Vertical clearance above deck: | 8.2 ft. [2.5 m] |
Owner: | Town or Township Highway Agency [03] |
Year built: | 1863 |
Year reconstructed: | 2017 |
Historic significance: | Bridge is on the National Register of Historic Places [1] |
Design load: | M 18 / H 20 [4] |
Main span material: | Wood or timber [7] |
Main span design: | Truss - Thru [10] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Wood or Timber [7] |
Latest Available Inspection: July 2018
Good/Fair/Poor Condition: | Good |
Status: | Posted for load [P] |
Average daily traffic: | 450 [as of 2008] |
Truck traffic: | 2% of total traffic |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge with "unknown" foundation that has not been evaluated for scour. [U] |
Sufficiency rating: | 63.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $511,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2018 | Good | Very Good | Very Good | Good | 450 | 63.0 |
December 2017 | Good | Very Good | Very Good | Very Good | 450 | 59.1 |
July 2016 | Poor | Satisfactory | Poor | Satisfactory | 450 | 20.9 |
July 2014 | Poor | Satisfactory | Poor | Satisfactory | 450 | 20.9 |
September 2013 | Poor | Satisfactory | Poor | Satisfactory | 450 | 20.9 |
June 2012 | Poor | Satisfactory | Poor | Satisfactory | 450 | 20.9 |
June 2010 | Poor | Satisfactory | Poor | Satisfactory | 450 | 8.7 |
September 2008 | Poor | Good | Poor | Satisfactory | 450 | 8.7 |
September 2006 | Poor | Satisfactory | Serious | Satisfactory | 450 | 4.3 |
June 2004 | Poor | Satisfactory | Serious | Fair | 450 | 10.8 |
December 2002 | Poor | Satisfactory | Poor | Poor | 450 | 35.8 |
November 2000 | Fair | Satisfactory | Fair | Fair | 450 | 44.6 |
September 1998 | Fair | Satisfactory | Fair | Fair | 450 | 8.7 |
August 1996 | Fair | Fair | Fair | Satisfactory | 400 | 5.8 |
August 1994 | Fair | Satisfactory | Fair | Fair | 400 | 10.1 |
September 1992 | Poor | Poor | Critical | Serious | 400 | 4.8 |
December 1991 | Poor | Poor | Critical | Serious | 400 | 1.8 |