Share:

TR 03 FAS 186 over DEAD CREEK

Map

Coordinates:
+44.18501, -73.31085
44°11'06" N, 73°18'39" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:TR 03 FAS 186 over DEAD CREEK
Structure number:200186001001052
Location:3.6 MI W JCT. VT.22A
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:86.9 ft. [26.5 m]
Total length:88.9 ft. [27.1 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:27.9 ft. [8.5 m]
Owner:Town or Township Highway Agency [03]
Year built:1948
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:1,650 [as of 1995]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:46.5 tons [42.3 metric tons]
Inventory rating:27.7 tons [25.2 metric tons]
Sufficiency rating:71.6
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$916,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201671.6FairSatisfactorySatisfactoryGood-1650
August 201471.6FairSatisfactoryGoodVery Good-1650
August 201275.8FairSatisfactoryGoodVery Good-1650
June 201075.8FairSatisfactorySatisfactoryGood-1650
June 200875.8FairSatisfactorySatisfactoryGood-1650
July 200676.0FairSatisfactorySatisfactoryGood-1650
August 200468.2FairSatisfactorySatisfactoryGood-1650
July 200268.2GoodGoodGoodGood-1650
August 200069.2FairSatisfactoryGoodGood-1650
June 199876.8FairSatisfactorySatisfactoryGood-1650
September 199677.0GoodGoodGoodGood-1650
September 199476.7GoodGoodGoodGood-1810
September 199276.7GoodGoodVery GoodGood-1810
September 199077.3GoodGoodGoodGood-850