Share:

SR 99 over DEXTER WAY N

Map

Coordinates:
+47.64920, -122.34733
47°38'57" N, 122°20'50" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 99 over DEXTER WAY N
Structure number:000000IC0000000
Location:7.4 N JCT SR 509
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:35.1 ft. [10.7 m]
Total length:35.1 ft. [10.7 m]
Roadway width between curbs:76.1 ft. [23.2 m]
Deck width edge-to-edge:106.0 ft. [32.3 m]
Vertical clearance below bridge:14.1 ft. [4.3 m]
Skew angle:25°
Owner:State Highway Agency [01]
Year built:1930
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Concrete [1]
Main span design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:57,150 [as of 2012]
Truck traffic:3% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:49.5 tons [45.0 metric tons]
Inventory rating:29.7 tons [27.0 metric tons]
Sufficiency rating:74.2

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201674.2FairGoodSatisfactoryGoodFO57150
March 201474.2FairGoodSatisfactoryGoodFO57150
March 201272.9FairGoodSatisfactoryGoodFO68070
May 201064.5FairSatisfactorySatisfactorySatisfactoryFO71189
June 200870.2FairSatisfactorySatisfactorySatisfactoryFO71589
May 200671.1FairSatisfactorySatisfactorySatisfactoryFO64232
April 200471.1FairSatisfactorySatisfactoryGoodFO64232
June 200271.1FairSatisfactorySatisfactoryGoodFO64232
February 200073.4FairSatisfactorySatisfactoryGoodFO64232
May 199663.5FairSatisfactorySatisfactoryGoodFO64232
December 199463.5FairSatisfactorySatisfactoryGoodFO64232
April 199267.4FairSatisfactorySatisfactoryGoodFO28475

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.278274040
Deck
Reinforced Concrete Decksq. ft.2,6602,657003
Wearing Surfacessq. ft.2,66002,66000
Substructure
Reinforced Concrete Columneach1616000
Reinforced Concrete Abutmentlinear ft.232230020
Joints
Open Jointlinear ft.168016800
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.7070000
Reinforced Concrete Bridge Raillinear ft.105103020