US 395 over RR
Map
Coordinates:
+48.77475, -118.1422848°46'29" N, 118°08'32" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 395 over RR |
Structure number: | 0002688A0000000 |
Location: | 10.9 N JCT SR 20 |
Purpose: | Carries highway and pedestrian walkway over railroad |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 65.9 ft. [20.1 m] |
Total length: | 191.9 ft. [58.5 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 29.9 ft. [9.1 m] |
Vertical clearance below bridge: | 23.0 ft. [7.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1941 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 5 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,029 [as of 2012] |
Truck traffic: | 23% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 67.5 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $2,304,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Satisfactory | Good | Good | 1029 | 67.5 |
April 2015 | Fair | Satisfactory | Good | Good | 1029 | 67.1 |
February 2014 | Fair | Satisfactory | Good | Good | 1029 | 67.1 |
April 2012 | Fair | Satisfactory | Good | Good | 1169 | 67.0 |
April 2010 | Fair | Satisfactory | Good | Good | 1229 | 67.0 |
April 2008 | Fair | Satisfactory | Good | Good | 1242 | 67.0 |
April 2006 | Fair | Satisfactory | Good | Good | 1391 | 65.8 |
July 2004 | Fair | Satisfactory | Good | Good | 1391 | 65.8 |
September 2002 | Fair | Satisfactory | Good | Good | 1391 | 66.8 |
June 2000 | Poor | Poor | Good | Good | 1391 | 60.8 |
June 1998 | Poor | Poor | Satisfactory | Good | 1391 | 61.8 |
March 1996 | Poor | Poor | Satisfactory | Good | 1391 | 54.1 |
May 1994 | Poor | Poor | Poor | Good | 1320 | 27.2 |
October 1992 | Good | Good | Good | Good | 1320 | 55.2 |
May 1990 | Poor | Poor | Poor | Good | 1320 | 23.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 768 | 768 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 4,608 | 4,604 | 0 | 0 | 4 |
Wearing Surfaces | sq. ft. | 4,608 | 0 | 4,597 | 6 | 5 |
Substructure |
Reinforced Concrete Column | each | 16 | 15 | 0 | 1 | 0 |
Reinforced Concrete Abutment | linear ft. | 2 | 2 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 144 | 144 | 0 | 0 | 0 |
Joints |
Open Joint | linear ft. | 96 | 0 | 0 | 0 | 96 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 384 | 384 | 0 | 0 | 0 |
Reinforced Concrete Bridge Rail | linear ft. | 384 | 376 | 0 | 8 | 0 |