SR 525 over POSSESSION SOUND
Map
Coordinates:
+47.97500, -122.3483347°58'30" N, 122°20'54" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 525 over POSSESSION SOUND |
Structure number: | 0004101A0000000 |
Location: | 1.9 N JCT SR 526 |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Tolls: | Yes [1] |
Length of largest span: | 80.1 ft. [24.4 m] |
Total length: | 105.0 ft. [32.0 m] |
Roadway width between curbs: | 20.0 ft. [6.1 m] |
Deck width edge-to-edge: | 24.0 ft. [7.3 m] |
Vertical clearance above deck: | 16.1 ft. [4.9 m] |
Owner: | State Highway Agency [01] |
Year built: | 1987 |
Year reconstructed: | 2000 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Main span material: | Steel [3] |
Main span design: | Movable - Lift [15] |
Deck type: | Closed Grating [4] |
Wearing surface: | Epoxy Overlay [5] |
Latest Available Inspection: June 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 12,000 [as of 2010] |
Truck traffic: | 5% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 48.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $1,008,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2017 | Fair | Good | Fair | Good | 12000 | 48.0 |
June 2015 | Fair | Good | Fair | Very Good | 12000 | 47.9 |
June 2013 | Fair | Good | Fair | Very Good | 12000 | 47.9 |
June 2011 | Fair | Very Good | Fair | Very Good | 12000 | 47.9 |
June 2010 | Fair | Very Good | Satisfactory | Very Good | 6127 | 76.0 |
June 2008 | Fair | Very Good | Satisfactory | Very Good | 6127 | 76.0 |
June 2006 | Fair | Very Good | Satisfactory | Very Good | 6800 | 76.0 |
August 2005 | Fair | Very Good | Satisfactory | Good | 5980 | 74.6 |
April 2003 | Fair | Very Good | Very Good | Satisfactory | 5980 | 74.6 |
June 2001 | Fair | Satisfactory | Fair | Satisfactory | 5980 | 63.6 |
August 2000 | Fair | Satisfactory | Fair | Satisfactory | 5980 | 63.6 |
April 1999 | Fair | Satisfactory | Fair | Satisfactory | 5980 | 61.6 |
May 1998 | Fair | Satisfactory | Fair | Satisfactory | 5980 | 61.6 |
March 1997 | Fair | Satisfactory | Fair | Satisfactory | 5980 | 61.6 |
April 1996 | Fair | Satisfactory | Fair | Satisfactory | 5980 | 61.6 |
April 1994 | Fair | Satisfactory | Fair | Satisfactory | 3808 | 45.5 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 180 | 178 | 0 | 2 | 0 |
Steel Protective Coating | sq. ft. | 806 | 749 | 50 | 5 | 2 |
Steel Stringer | linear ft. | 450 | 450 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 2,015 | 1,874 | 126 | 14 | 1 |
Steel Floor Beam | linear ft. | 272 | 254 | 0 | 18 | 0 |
Steel Protective Coating | sq. ft. | 1,218 | 1,133 | 76 | 8 | 1 |
Steel Pin or Pin & Hangar Assembly | each | 6 | 6 | 0 | 0 | 0 |
Substructure |
Steel Pile | each | 20 | 20 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 89 | 83 | 5 | 0 | 1 |
Reinforced Concrete Pier Cap | linear ft. | 24 | 24 | 0 | 0 | 0 |
Deck |
Concrete Filled Grid Deck | sq. ft. | 1,800 | 1,710 | 0 | 90 | 0 |
Wearing Surfaces | sq. ft. | 1,800 | 0 | 1,796 | 0 | 4 |
Joints |
Compression Joint | linear ft. | 20 | 0 | 0 | 20 | 0 |
Assembly without Seal Joint | linear ft. | 20 | 0 | 20 | 0 | 0 |
Bearings |
Fixed Bearing | each | 2 | 2 | 0 | 0 | 0 |