I-5 over COWLITZ RIVER
Map
Coordinates:
+46.41287, -122.8900046°24'46" N, 122°53'24" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-5 over COWLITZ RIVER |
Structure number: | 0004367B0000000 |
Location: | 2.0 N COWLITZ CO |
Purpose: | Carries highway over highway and waterway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 240.2 ft. [73.2 m] |
Total length: | 759.9 ft. [231.6 m] |
Roadway width between curbs: | 31.8 ft. [9.7 m] |
Deck width edge-to-edge: | 33.5 ft. [10.2 m] |
Vertical clearance above deck: | 14.4 ft. [4.4 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1953 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: June 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 22,119 [as of 2012] |
Truck traffic: | 20% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 55.3 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $13,680,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2017 | Fair | Fair | Fair | Good | 22119 | 55.3 |
June 2015 | Poor | Fair | Poor | Good | 22119 | 48.4 |
June 2013 | Fair | Satisfactory | Fair | Good | 21843 | 61.7 |
June 2011 | Fair | Satisfactory | Fair | Good | 21843 | 61.7 |
June 2009 | Fair | Satisfactory | Fair | Good | 22600 | 63.7 |
June 2007 | Fair | Fair | Fair | Good | 19563 | 63.1 |
May 2005 | Fair | Fair | Fair | Good | 19563 | 63.1 |
October 2003 | Fair | Fair | Fair | Good | 19563 | 63.1 |
March 2002 | Fair | Fair | Fair | Good | 19563 | 63.1 |
March 2001 | Fair | Fair | Fair | Fair | 19563 | 63.1 |
August 2000 | Fair | Satisfactory | Fair | Fair | 18387 | 64.3 |
March 1999 | Fair | Satisfactory | Fair | Fair | 18387 | 64.3 |
March 1997 | Fair | Satisfactory | Fair | Fair | 18387 | 64.3 |
April 1996 | Fair | Satisfactory | Fair | Good | 18387 | 66.3 |
June 1995 | Fair | Satisfactory | Fair | Good | 18387 | 66.3 |
April 1993 | Poor | Satisfactory | Poor | Good | 14950 | 52.2 |
July 1990 | Fair | Fair | Satisfactory | Good | 14950 | 78.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 1,084 | 1,084 | 0 | 0 | 0 |
Steel Stringer | linear ft. | 3,360 | 3,288 | 10 | 2 | 60 |
Steel Protective Coating | sq. ft. | 21,821 | 18,110 | 0 | 2,474 | 1,237 |
Deck |
Reinforced Concrete Deck | sq. ft. | 24,244 | 23,999 | 198 | 0 | 47 |
Superstructure |
Steel Truss | linear ft. | 960 | 720 | 180 | 60 | 0 |
Steel Protective Coating | sq. ft. | 62,345 | 51,742 | 0 | 7,068 | 3,535 |
Steel Floor Beam | linear ft. | 621 | 620 | 0 | 1 | 0 |
Steel Protective Coating | sq. ft. | 4,033 | 3,347 | 0 | 457 | 229 |
Steel Gusset Plate | each | 64 | 64 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 12 | 12 | 0 | 0 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 123 | 123 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 35 | 35 | 0 | 0 | 0 |
Joints |
Pourable Joint | linear ft. | 64 | 0 | 0 | 0 | 64 |
Open Joint | linear ft. | 448 | 0 | 256 | 160 | 32 |
Assembly without Seal Joint | linear ft. | 96 | 0 | 64 | 32 | 0 |
Bearings |
Movable Bearing | each | 12 | 10 | 0 | 2 | 0 |
Fixed Bearing | each | 4 | 2 | 0 | 2 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 1,520 | 1,512 | 0 | 8 | 0 |