SR 529 over STEAMBOAT SLOUGH
Map
Coordinates:
+48.03489, -122.1815048°02'06" N, 122°10'53" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | SR 529 over STEAMBOAT SLOUGH |
Structure number: | 0004373A0000000 |
Location: | 6.6 N JCT I-5 |
Purpose: | Carries highway and pedestrian walkway over highway and waterway |
Route classification: | Principal Arterial - Other Freeways or Expressways (Urban) [12] |
Length of largest span: | 182.1 ft. [55.5 m] |
Total length: | 910.1 ft. [277.4 m] |
Roadway width between curbs: | 27.9 ft. [8.5 m] |
Deck width edge-to-edge: | 34.1 ft. [10.4 m] |
Vertical clearance above deck: | 15.1 ft. [4.6 m] |
Vertical clearance below bridge: | 3.3 ft. [1.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1954 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 2 |
Main spans material: | Steel [3] |
Main spans design: | Movable - Swing [17] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Epoxy Overlay [5] |
Latest Available Inspection: December 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 16,379 [as of 2016] |
Truck traffic: | 6% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Underclearances appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Pier/abutment protection: | In place and functioning [2] |
Scour condition: | Bridge is scour critical; bridge foundations determined to be unstable. [3] |
Sufficiency rating: | 54.4 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $11,648,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
December 2018 | Fair | Satisfactory | Fair | Satisfactory | 16379 | 54.4 |
July 2016 | Fair | Satisfactory | Fair | Satisfactory | 14943 | 57.7 |
July 2014 | Fair | Satisfactory | Fair | Satisfactory | 14943 | 57.7 |
July 2012 | Fair | Satisfactory | Fair | Good | 15190 | 57.6 |
July 2010 | Fair | Satisfactory | Fair | Good | 15839 | 57.5 |
July 2008 | Fair | Satisfactory | Fair | Good | 15839 | 57.5 |
July 2006 | Fair | Satisfactory | Fair | Good | 10955 | 58.3 |
September 2004 | Fair | Satisfactory | Fair | Good | 10955 | 58.3 |
November 2003 | Fair | Satisfactory | Satisfactory | Good | 10955 | 69.6 |
April 2001 | Fair | Satisfactory | Fair | Good | 10955 | 58.3 |
November 2000 | Fair | Satisfactory | Fair | Good | 10955 | 58.3 |
May 1999 | Fair | Satisfactory | Satisfactory | Good | 10955 | 69.6 |
April 1997 | Fair | Good | Satisfactory | Good | 10955 | 69.6 |
February 1996 | Fair | Good | Satisfactory | Good | 10955 | 69.9 |
December 1994 | Fair | Good | Satisfactory | Good | 10955 | 69.9 |
May 1993 | Fair | Good | Satisfactory | Good | 12950 | 73.7 |
November 1991 | Poor | Serious | Good | Good | 9900 | 70.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 165 | 165 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,032 | 1,032 | 0 | 0 | 0 |
Reinforced Concrete Girder/Beam | linear ft. | 3,528 | 3,513 | 0 | 15 | 0 |
Steel Stringer | linear ft. | 3,848 | 3,781 | 67 | 0 | 0 |
Steel Protective Coating | sq. ft. | 24,069 | 24,069 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 25,480 | 25,425 | 23 | 0 | 32 |
Wearing Surfaces | sq. ft. | 25,480 | 0 | 22,252 | 128 | 3,100 |
Superstructure |
Steel Truss | linear ft. | 1,312 | 1,014 | 0 | 298 | 0 |
Steel Protective Coating | sq. ft. | 82,067 | 82,067 | 0 | 0 | 0 |
Steel Floor Beam | linear ft. | 1,116 | 1,110 | 0 | 6 | 0 |
Steel Protective Coating | sq. ft. | 6,980 | 6,980 | 0 | 0 | 0 |
Steel Gusset Plate | each | 112 | 109 | 0 | 3 | 0 |
Substructure |
Reinforced Concrete Column | each | 48 | 48 | 0 | 0 | 0 |
Reinforced Concrete Pier Wall | linear ft. | 266 | 266 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 64 | 64 | 0 | 0 | 0 |
Reinforced Concrete Pile Cap/Footing | linear ft. | 4 | 3 | 0 | 1 | 0 |
Reinforced Concrete Pile | each | 9 | 3 | 0 | 6 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 396 | 396 | 0 | 0 | 0 |
Joints |
Open Joint | linear ft. | 756 | 0 | 280 | 364 | 112 |
Assembly without Seal Joint | linear ft. | 56 | 0 | 56 | 0 | 0 |
Bearings |
Movable Bearing | each | 8 | 8 | 0 | 0 | 0 |
Enclosed/Concealed Bearing | each | 1 | 1 | 0 | 0 | 0 |
Fixed Bearing | each | 4 | 4 | 0 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 1,312 | 1,308 | 4 | 0 | 0 |