Share:

SR 3 over ERLAND POINT RD

Map

Coordinates:
+47.59643, -122.69909
47°35'47" N, 122°41'57" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR 3 over ERLAND POINT RD
Structure number:0007883C0000000
Location:5.6 N JCT SR 304
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:56.1 ft. [17.1 m]
Total length:160.1 ft. [48.8 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:35.1 ft. [10.7 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1966
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:26,456 [as of 2012]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:77.8
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$2,688,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017FairGoodSatisfactorySatisfactory2645677.8
April 2015FairGoodSatisfactorySatisfactory2645677.8
April 2013FairGoodSatisfactorySatisfactory2590777.9
May 2011FairGoodSatisfactorySatisfactory2590776.9
June 2009FairGoodSatisfactorySatisfactory2612776.9
July 2007FairGoodSatisfactorySatisfactory2415078.1
August 2005FairGoodSatisfactorySatisfactory2415077.1
November 2003FairGoodSatisfactorySatisfactory2415069.2
November 2002FairSatisfactorySatisfactorySatisfactory2415069.2
November 2000FairSatisfactorySatisfactorySatisfactory2415068.2
April 1998FairGoodGoodSatisfactory2415068.2
March 1996FairGoodGoodSatisfactory1855364.8
March 1994FairGoodGoodSatisfactory1160065.6
June 1992FairFairGoodSatisfactory1160078.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.9609005640
Deck
Reinforced Concrete Decksq. ft.4,8004,797003
Wearing Surfacessq. ft.4,80004,80000
Substructure
Reinforced Concrete Columneach44000
Reinforced Concrete Abutmentlinear ft.101101000
Reinforced Concrete Pier Caplinear ft.6060000
Joints
Pourable Jointlinear ft.6006000
Bearings
Elastomeric Bearingeach1212000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.320320000
Reinforced Concrete Bridge Raillinear ft.320320000