Share:

I-90 REV LANES over RAINIER AVE S

Map

Coordinates:
+47.59019, -122.30778
47°35'25" N, 122°18'28" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:I-90 REV LANES over RAINIER AVE S
Structure number:0013725C0000000
Location:0.6 E JCT I-5
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:119.1 ft. [36.3 m]
Total length:298.9 ft. [91.1 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:44.9 ft. [13.7 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Skew angle:27°
Owner:State Highway Agency [01]
Year built:1991
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: September 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:2,069 [as of 2016]
Truck traffic:28% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:100.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$5,262,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2017GoodGoodGoodGood2069100.0
September 2015GoodGoodGoodGood1838100.0
September 2013GoodGoodGoodGood1838100.0
September 2011GoodGoodGoodGood1492100.0
September 2009GoodGoodGoodGood176998.0
November 2007GoodGoodGoodGood179798.0
December 2005GoodGoodGoodGood67898.0
December 2003GoodGoodGoodGood67898.0
November 2001GoodGoodGoodGood67898.0
May 1999GoodGoodGoodGood67898.0
May 1997GoodGoodGoodGood67898.0
September 1995GoodGoodGoodGood67898.0
November 1993GoodGoodGoodGood100096.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.299299000
Deck
Reinforced Concrete Decksq. ft.12,55812,558000
Wearing Surfacessq. ft.12,558012,55800
Substructure
Reinforced Concrete Columneach44000
Reinforced Concrete Abutmentlinear ft.101101000
Joints
Compression Jointlinear ft.9409400
Open Jointlinear ft.8408400
Bearings
Movable Bearingeach66000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.896896000