FERRY STREET over KETTLE RIVER
Map
Coordinates:
+48.88556, -118.6013948°53'08" N, 118°36'05" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FERRY STREET over KETTLE RIVER |
Structure number: | 081665000000000 |
Location: | 00.0 E 21 IN CURLEW |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Minor Collector (Rural) [08] |
Length of largest span: | 180.1 ft. [54.9 m] |
Total length: | 202.1 ft. [61.6 m] |
Roadway width between curbs: | 13.8 ft. [4.2 m] |
Deck width edge-to-edge: | 18.4 ft. [5.6 m] |
Vertical clearance above deck: | 12.1 ft. [3.7 m] |
Owner: | County Highway Agency [02] |
Year built: | 1908 |
Year reconstructed: | 2006 |
Historic significance: | Bridge is on the National Register of Historic Places [1] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Wood or Timber [7] |
Latest Available Inspection: July 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 176 [as of 2016] |
Truck traffic: | 5% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Basically intolerable requiring high priority of replacement [2] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 49.1 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $1,293,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
July 2017 | Fair | Satisfactory | Good | Good | 176 | 49.1 |
July 2016 | Fair | Satisfactory | Good | Good | 176 | 49.5 |
September 2014 | Good | Good | Good | Good | 176 | 49.5 |
September 2013 | Good | Good | Good | Good | 176 | 49.5 |
September 2011 | Good | Good | Good | Good | 176 | 49.5 |
July 2009 | Good | Good | Good | Good | 176 | 49.5 |
August 2007 | Good | Good | Good | Good | 435 | 49.4 |
August 2002 | Fair | Satisfactory | Fair | Satisfactory | 435 | 32.1 |
September 2000 | Fair | Satisfactory | Satisfactory | Satisfactory | 435 | 42.2 |
October 1998 | Fair | Good | Satisfactory | Satisfactory | 435 | 42.2 |
August 1996 | Fair | Good | Satisfactory | Satisfactory | 435 | 42.2 |
September 1994 | Fair | Good | Satisfactory | Satisfactory | 435 | 27.1 |
December 1993 | Poor | Good | Poor | Satisfactory | 435 | 19.4 |
July 1992 | Poor | Good | Poor | Satisfactory | 435 | 15.1 |