Facts 

Name:FAUNTLEROY WAY over ADMIRAL WAY, AVALON WAY
Structure number:085192000000000
Location:Fauntleroy Way & 35th Ave
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:128.0 ft. [39.0 m]
Total length:3123.2 ft. [951.9 m]
Roadway width between curbs:56.1 ft. [17.1 m]
Deck width edge-to-edge:60.7 ft. [18.5 m]
Vertical clearance below bridge:14.1 ft. [4.3 m]
Skew angle:55°
Owner:City or Municipal Highway Agency [04]
Year built:1963
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:38
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: March 2017 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:52,700 [as of 2014]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:33.9 tons [30.8 metric tons]
Inventory rating:20.9 tons [19.0 metric tons]
Sufficiency rating:67.2
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$11,380,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201767.2FairSatisfactorySatisfactorySatisfactoryFO52700
March 201574.3FairSatisfactorySatisfactorySatisfactory-44996
March 201351.5FairSatisfactorySatisfactorySatisfactoryFO56900
March 201151.5FairSatisfactorySatisfactorySatisfactoryFO56900
November 201051.5FairSatisfactorySatisfactorySatisfactoryFO56900
July 200952.6FairSatisfactorySatisfactorySatisfactoryFO50500
November 200853.8FairSatisfactorySatisfactorySatisfactoryFO50500
August 200694.2FairSatisfactorySatisfactoryGood-50500
April 200594.2FairSatisfactoryGoodGood-50500
June 200395.5FairSatisfactoryGoodGood-37200
September 200294.4FairFairGoodGood-37200
August 200094.4FairFairGoodGood-37200
April 199994.4FairFairGoodGood-37200
July 199894.4FairFairGoodGood-37200
February 199794.4FairFairGoodGood-37200
May 199595.1FairFairGoodGood-37200
June 199295.1FairFairGoodGood-37200
July 199195.1FairFairGoodGood-37200