Share:

CTH P over TREMPEALEAU RIVER

Map

Coordinates:
+44.13194, -91.55278
44°07'55" N, 91°33'10" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CTH P over TREMPEALEAU RIVER
Structure number:B06002200000000
Location:0.1M W JCT CTH J
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:45.9 ft. [14.0 m]
Total length:121.1 ft. [36.9 m]
Roadway width between curbs:24.0 ft. [7.3 m]
Deck width edge-to-edge:26.6 ft. [8.1 m]
Owner:County Highway Agency [02]
Year built:1955
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:325 [as of 2015]
Deck condition:Serious [3 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:57.8
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$587,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018PoorSeriousFairFair32557.8
October 2017PoorPoorFairSatisfactory32559.8
October 2016PoorPoorSatisfactorySatisfactory32570.0
October 2015PoorPoorSatisfactorySatisfactory32570.0
October 2014PoorPoorSatisfactorySatisfactory30070.0
October 2012PoorPoorSatisfactorySatisfactory30068.0
October 2010PoorPoorSatisfactorySatisfactory30073.5
November 2008FairFairSatisfactorySatisfactory30075.6
December 2007FairSatisfactorySatisfactorySatisfactory30076.6
October 2006FairSatisfactorySatisfactorySatisfactory30076.6
October 2004PoorSatisfactorySatisfactoryPoor30049.1
October 2002PoorGoodSatisfactoryPoor30049.1
September 2000PoorGoodGoodPoor30049.1
September 1998PoorVery GoodVery GoodPoor30049.1
March 1996PoorVery GoodVery GoodPoor51047.3
March 1994PoorVery GoodVery GoodPoor51049.0
March 1992PoorVery GoodVery GoodPoor39047.4
February 1990PoorVery GoodVery GoodPoor39047.4