STH 32-STH 57 over KILLSNAKE RIVER
Map
Coordinates:
+44.06027, -88.1630144°03'37" N, 88°09'47" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | STH 32-STH 57 over KILLSNAKE RIVER |
Structure number: | B08001400000000 |
Location: | 2.2M N JCT USH 151 TO S |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 55.1 ft. [16.8 m] |
Total length: | 110.6 ft. [33.7 m] |
Roadway width between curbs: | 40.0 ft. [12.2 m] |
Deck width edge-to-edge: | 43.0 ft. [13.1 m] |
Skew angle: | 10° |
Owner: | State Highway Agency [01] |
Year built: | 1983 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 2 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: February 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 7,900 [as of 2018] |
Truck traffic: | 9% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 83.9 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
February 2018 | Fair | Satisfactory | Satisfactory | Good | 7900 | 83.9 |
February 2016 | Good | Good | Good | Good | 7000 | 83.9 |
February 2014 | Good | Good | Good | Good | 6630 | 83.9 |
February 2012 | Good | Good | Good | Good | 6630 | 83.9 |
February 2010 | Good | Good | Good | Good | 6630 | 83.9 |
February 2008 | Good | Good | Good | Good | 6630 | 83.9 |
February 2006 | Good | Good | Good | Good | 6630 | 83.9 |
February 2004 | Good | Good | Good | Good | 6630 | 83.9 |
September 2001 | Good | Good | Good | Good | 5130 | 85.5 |
December 1998 | Fair | Fair | Fair | Satisfactory | 5130 | 71.9 |
December 1997 | Fair | Fair | Fair | Satisfactory | 5130 | 71.9 |
November 1996 | Fair | Fair | Fair | Satisfactory | 5130 | 71.9 |
September 1995 | Fair | Fair | Fair | Satisfactory | 5130 | 71.9 |
December 1994 | Fair | Fair | Fair | Satisfactory | 5130 | 71.9 |
October 1993 | Fair | Fair | Fair | Satisfactory | 5300 | 71.9 |
October 1992 | Fair | Satisfactory | Satisfactory | Satisfactory | 5300 | 83.9 |
October 1991 | Fair | Satisfactory | Satisfactory | Satisfactory | 5300 | 83.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Deck |
Reinforced Concrete Deck | sq. ft. | 4,756 | 4,715 | 41 | 0 | 0 |
Substructure |
Steel Column | each | 12 | 0 | 12 | 0 | 0 |
Steel Protective Coating | sq. ft. | 225 | 135 | 90 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 88 | 87 | 1 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 45 | 45 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 258 | 236 | 22 | 0 | 0 |