Share:

IH 43 NB over LRD CLOVER RD

Map

Coordinates:
+44.03765, -87.70572
44°02'16" N, 87°42'21" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:IH 43 NB over LRD CLOVER RD
Structure number:B36005700000000
Location:8.5M N JCT CTH XX
Purpose:Carries highway over highway
Route classification:Principal Arterial - Interstate (Rural) [01]
Length of largest span:57.1 ft. [17.4 m]
Total length:118.4 ft. [36.1 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:43.0 ft. [13.1 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:1979
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:10,050 [as of 2017]
Truck traffic:20% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:85.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2017GoodGoodGoodGood1005085.0
September 2015FairSatisfactorySatisfactoryGood1005085.0
September 2013GoodGoodGoodGood1760085.0
September 2011GoodGoodGoodGood1760085.0
September 2009GoodGoodGoodGood1760085.0
September 2007GoodGoodGoodGood1760085.0
September 2005FairSatisfactorySatisfactoryGood1760085.0
October 2003FairSatisfactorySatisfactorySatisfactory1760085.0
October 2001FairSatisfactorySatisfactorySatisfactory1760085.0
December 1999FairFairFairSatisfactory1760073.0
December 1998FairFairFairSatisfactory1760073.0
July 1997FairFairFairSatisfactory1760073.0
November 1996FairFairFairSatisfactory1760073.0
March 1996FairFairFairSatisfactory1760073.0
December 1994FairFairFairSatisfactory1760073.0
December 1993FairFairFairSatisfactory436075.7
January 1993FairSatisfactorySatisfactorySatisfactory436089.1
January 1992FairSatisfactorySatisfactorySatisfactory436089.1

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Columneach88000
Reinforced Concrete Abutmentlinear ft.85721300
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.2391746500
Deck
Reinforced Concrete Slabsq. ft.5,1004,91019000
Wearing Surfacessq. ft.4,7444,62412000