Share:

IH 794 WB-LAKE INT over IH RAMP, LINCOLN MEMORIA

Map 

Coordinates:
+43.03479, -87.90048
43°02'05" N, 87°54'02" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:IH 794 WB-LAKE INT over IH RAMP, LINCOLN MEMORIA
Structure number:B400400002E0000
Location:2.3 MI W JCT CARFERRY DR
Purpose:Carries highway overpass (third level) over highway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:117.1 ft. [35.7 m]
Total length:331.1 ft. [100.9 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:44.0 ft. [13.4 m]
Vertical clearance above deck:18.4 ft. [5.6 m]
Vertical clearance below bridge:14.8 ft. [4.5 m]
Owner:State Highway Agency [01]
Year built:1975
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 18 / H 20 [4]
Number of main spans:4
Main spans material:Prestressed concrete continuous [6]
Main spans design:Box beam or girders - Multiple [05]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Low slump Concrete [4]

Latest Available Inspection: August 2015 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:22,600 [as of 2013]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Basically intolerable requiring high priority of replacement [2]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:79.0 tons [71.8 metric tons]
Inventory rating:48.1 tons [43.7 metric tons]
Sufficiency rating:92.9
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$1,962,000

Previous Inspections 

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
August 201592.9FairSatisfactorySatisfactorySatisfactoryFO22600
February 201483.8FairFairFairSatisfactory-22600
March 201281.4FairFairFairSatisfactory-10100
March 201075.7FairFairFairSatisfactoryFO9500
March 200875.1FairFairFairGoodFO11150
June 200786.7FairFairSatisfactoryGoodFO11150
June 200586.7FairFairSatisfactoryGoodFO11150
July 200390.8FairFairSatisfactoryGood-11150
October 200290.8FairFairSatisfactoryGood-11150
November 200187.4FairFairSatisfactoryGoodFO8810
October 200088.4FairSatisfactorySatisfactoryGoodFO8810
November 199988.2FairSatisfactorySatisfactoryGoodFO16280
October 199888.2FairSatisfactoryGoodGoodFO16280
December 199688.2FairSatisfactoryGoodVery GoodFO16280
February 199692.1FairSatisfactoryGoodVery Good-16280
December 199492.1FairSatisfactoryGoodVery Good-16280
February 199495.5FairSatisfactoryGoodVery Good-5120
February 199395.5FairSatisfactoryVery GoodVery Good-5120
September 199195.5FairSatisfactoryVery GoodVery Good-5120