Share:

WV ROUTE 2 SPUR over WEST VIRGINIA RTE 2 SPUR

Map

Coordinates:
+40.35825, -80.60935
40°21'30" N, 80°36'34" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:WV ROUTE 2 SPUR over WEST VIRGINIA RTE 2 SPUR
Structure number:00000000005A006
Location:0.34 Mi West Jct. WV 2
Purpose:Carries highway and pedestrian walkway over highway, waterway, and railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:700.2 ft. [213.4 m]
Total length:1794.4 ft. [546.9 m]
Roadway width between curbs:20.7 ft. [6.3 m]
Deck width edge-to-edge:21.3 ft. [6.5 m]
Vertical clearance above deck:9.8 ft. [3.0 m]
Vertical clearance below bridge:72.2 ft. [22.0 m]
Owner:State Highway Agency [01]
Year built:1904
Year reconstructed:2011
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Steel [3]
Main span design:Suspension [13]
Deck type:Open Grating [3]
Wearing surface:Other [9]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:7,834 [as of 2017]
Deck condition:Good [7 out of 9]
Superstructure condition:Serious [3 out of 9]
Substructure condition:Serious [3 out of 9]
Structural appraisal:Basically intolerable requiring high priority of replacement [2]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Pier/abutment protection:None present but re-evaluation suggested [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:10.0
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$102,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2018PoorGoodSeriousSerious783410.0
June 2016PoorGoodSeriousSerious150001.0
June 2015PoorGoodSeriousSerious150001.0
June 2014PoorGoodSeriousSerious150001.0
June 2013PoorGoodSeriousSerious60001.0
June 2012PoorGoodSeriousSerious60001.0
September 2011PoorImminent FailureImminent FailureImminent Failure-30.0
September 2010PoorImminent FailureImminent FailureImminent Failure-30.0
September 2009PoorGoodSeriousSerious150001.0
September 2008PoorGoodSeriousSerious150001.0
September 2007PoorGoodSeriousSerious64001.0
September 2006PoorGoodSeriousSerious64001.0
September 2005PoorGoodSeriousSerious150001.0
September 2004PoorGoodSeriousSerious150001.0
September 2003PoorGoodSeriousFair150001.0
September 2002PoorGoodSeriousFair150001.0
September 2000PoorGoodSeriousFair150001.0
September 1999PoorGoodSeriousFair150001.0
September 1998PoorGoodSeriousFair150001.0
September 1997PoorGoodSeriousFair140001.0
September 1996PoorGoodSeriousFair105001.0
September 1995PoorGoodSeriousFair105000.0
September 1994PoorGoodSeriousFair105000.0
September 1993PoorGoodSeriousFair97000.0
January 1993PoorGoodSeriousGood97001.0
July 1991PoorGoodSeriousFair97001.0