Name: | I-64 E & W over KAN R WV61 CSX RR US119 |
Structure number: | 00000000020A397 |
Location: | 2.03 MI E OF CR 60/64 |
Purpose: | Carries highway over highway, waterway, and railroad |
Route classification: | Principal Arterial - Interstate (Urban) [11] |
Length of largest span: | 464.9 ft. [141.7 m] |
Total length: | 2247.2 ft. [684.9 m] |
Roadway width between curbs: | 105.0 ft. [32.0 m] |
Deck width edge-to-edge: | 113.2 ft. [34.5 m] |
Vertical clearance above deck: | 16.7 ft. [5.1 m] |
Vertical clearance below bridge: | 88.6 ft. [27.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1975 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Steel [3] |
Main span design: | Truss - Thru [10] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 132,620 [as of 2014] |
Truck traffic: | 12% of total traffic |
Deck condition: | Fair [5 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 65.0 |
Recommended work: | Bridge deck rehabilitation with only incidental widening. [36] |
Estimated cost of work: | $7,500,000 |
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|---|---|---|---|---|---|
October 2018 | Fair | Fair | Fair | Satisfactory | 132620 | 65.0 |
October 2016 | Fair | Fair | Satisfactory | Satisfactory | 107000 | 76.0 |
October 2014 | Fair | Fair | Satisfactory | Satisfactory | 107000 | 76.0 |
August 2013 | Fair | Fair | Satisfactory | Good | 107000 | 76.0 |
September 2012 | Fair | Fair | Satisfactory | Good | 107000 | 76.0 |
September 2011 | Fair | Satisfactory | Satisfactory | Satisfactory | 107000 | 82.0 |
September 2010 | Fair | Satisfactory | Satisfactory | Satisfactory | 107000 | 77.0 |
September 2009 | Fair | Satisfactory | Satisfactory | Satisfactory | 107000 | 73.9 |
October 2008 | Fair | Satisfactory | Satisfactory | Satisfactory | 107000 | 73.9 |
March 2008 | Fair | Satisfactory | Satisfactory | Satisfactory | 99999 | 73.9 |
March 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 99999 | 73.9 |
March 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 83000 | 57.2 |
March 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 83000 | 57.2 |
March 2001 | Fair | Satisfactory | Good | Satisfactory | 81000 | 57.2 |
March 2000 | Fair | Satisfactory | Good | Satisfactory | 81000 | 57.2 |
June 1998 | - | - | - | - | 6000 | 0.0 |
August 1997 | Fair | Very Good | Very Good | Satisfactory | 90500 | 57.2 |
March 1996 | Fair | Very Good | Very Good | Satisfactory | 89000 | 57.2 |
January 1994 | Good | Very Good | Very Good | Good | 89000 | 57.2 |
February 1992 | Good | Very Good | Very Good | Good | 89000 | 58.2 |
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|---|---|---|---|---|---|
Superstructure | ||||||
Reinforced Concrete Closed Web/Box Girder | linear ft. | 8,508 | 7,330 | 1,156 | 22 | 0 |
Steel Girder/Beam | linear ft. | 13,528 | 13,432 | 48 | 48 | 0 |
Steel Protective Coating | sq. ft. | 250,571 | 250,571 | 0 | 0 | 0 |
Steel Stringer | linear ft. | 16,490 | 16,483 | 7 | 0 | 0 |
Steel Protective Coating | sq. ft. | 58,768 | 58,768 | 0 | 0 | 0 |
Deck | ||||||
Reinforced Concrete Deck | sq. ft. | 204,183 | 193,086 | 8,009 | 3,088 | 0 |
Wearing Surfaces | sq. ft. | 204,183 | 195,800 | 901 | 7,482 | 0 |
Superstructure | ||||||
Steel Truss | linear ft. | 930 | 912 | 16 | 2 | 0 |
Steel Protective Coating | sq. ft. | 13,624 | 13,624 | 0 | 0 | 0 |
Steel Floor Beam | linear ft. | 9,578 | 9,563 | 10 | 5 | 0 |
Steel Protective Coating | sq. ft. | 66,482 | 66,482 | 0 | 0 | 0 |
Deck | ||||||
Reinforced Concrete Top Flange | sq. ft. | 62,193 | 62,193 | 0 | 0 | 0 |
Wearing Surfaces | sq. ft. | 62,193 | 62,163 | 30 | 0 | 0 |
Superstructure | ||||||
Steel Gusset Plate | each | 72 | 62 | 2 | 8 | 0 |
Steel Protective Coating | sq. ft. | 4,320 | 4,320 | 0 | 0 | 0 |
Substructure | ||||||
Reinforced Concrete Column | each | 76 | 57 | 16 | 3 | 0 |
Concrete Protective Coating | sq. ft. | 61,385 | 61,385 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 119 | 15 | 33 | 71 | 0 |
Concrete Protective Coating | sq. ft. | 1,440 | 1,440 | 0 | 0 | 0 |
Steel Pier Cap | linear ft. | 232 | 192 | 0 | 40 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 1,128 | 1,065 | 55 | 8 | 0 |
Concrete Protective Coating | sq. ft. | 29,934 | 29,934 | 0 | 0 | 0 |
Joints | ||||||
Strip Seal Joint | linear ft. | 836 | 0 | 836 | 0 | 0 |
Assembly without Seal Joint | linear ft. | 272 | 0 | 272 | 0 | 0 |
Bearings | ||||||
Movable Bearing | each | 107 | 98 | 1 | 8 | 0 |
Steel Protective Coating | sq. ft. | 535 | 535 | 0 | 0 | 0 |
Fixed Bearing | each | 49 | 45 | 4 | 0 | 0 |
Steel Protective Coating | sq. ft. | 255 | 255 | 0 | 0 | 0 |
Bridge Rail | ||||||
Reinforced Concrete Bridge Rail | linear ft. | 12,424 | 12,316 | 102 | 6 | 0 |
Concrete Protective Coating | sq. ft. | 91,703 | 91,703 | 0 | 0 | 0 |