Share:

MARION CO RT 1 over DENTS RUN

Map

Coordinates:
+39.52638, -80.36669
39°31'35" N, 80°22'00" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:MARION CO RT 1 over DENTS RUN
Structure number:00000000025A003
Location:0.11 MI WEST CO RT 5
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:24.0 ft. [7.3 m]
Total length:26.9 ft. [8.2 m]
Roadway width between curbs:22.6 ft. [6.9 m]
Deck width edge-to-edge:24.0 ft. [7.3 m]
Owner:State Highway Agency [01]
Year built:1959
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Channel beam [22]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2015

Good/Fair/Poor Condition:Poor
Status:Open, no restriction [A]
Average daily traffic:2,100 [as of 2011]
Truck traffic:9% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:54.9 tons [49.9 metric tons]
Inventory rating:25.0 tons [22.7 metric tons]
Sufficiency rating:43.2
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$388,000

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
February 201543.2PoorFairPoorSatisfactorySD2100
February 201343.2PoorFairPoorSatisfactorySD2100
February 201168.0FairFairFairSatisfactoryFO1400
March 200968.0FairFairFairSatisfactoryFO1400
March 200768.0FairFairFairSatisfactoryFO1400
February 200568.0FairFairFairSatisfactoryFO1400
February 200368.0FairFairFairSatisfactoryFO1400
January 200166.0FairFairFairSatisfactoryFO1400
January 199966.0FairFairFairSatisfactoryFO1500
January 199766.0FairFairFairSatisfactoryFO1200
February 199566.0FairFairFairSatisfactoryFO1500
February 199378.0FairSatisfactorySatisfactorySatisfactoryFO1500