I-64 WBL over CR 7 AND CSX RAILROAD
Map
Coordinates:
+37.78079, -80.8954437°46'51" N, 80°53'44" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | I-64 WBL over CR 7 AND CSX RAILROAD |
Structure number: | 00000000045A067 |
Location: | 0.30 Miles W. of WV 20 |
Purpose: | Carries highway over highway and railroad |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Length of largest span: | 110.2 ft. [33.6 m] |
Total length: | 532.2 ft. [162.2 m] |
Roadway width between curbs: | 45.6 ft. [13.9 m] |
Deck width edge-to-edge: | 49.2 ft. [15.0 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Skew angle: | 99° |
Owner: | State Highway Agency [01] |
Year built: | 1985 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 6 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: June 2018
Good/Fair/Poor Condition: | Poor |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,891 [as of 2015] |
Truck traffic: | 29% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Poor [4 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Underclearances appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 67.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
June 2018 | Poor | Satisfactory | Fair | Poor | 4891 | 67.0 |
June 2016 | Fair | Satisfactory | Fair | Fair | 4891 | 83.0 |
June 2014 | Fair | Satisfactory | Fair | Fair | 5748 | 83.0 |
May 2012 | Fair | Good | Good | Satisfactory | 4750 | 94.0 |
May 2010 | Fair | Good | Satisfactory | Good | 6500 | 93.1 |
June 2006 | Good | Good | Good | Good | 6500 | 93.1 |
July 2004 | Good | Good | Good | Good | 6000 | 93.1 |
August 2002 | Good | Good | Good | Good | 6000 | 93.1 |
August 2000 | Good | Good | Good | Good | 5000 | 93.2 |
July 1998 | Good | Good | Good | Good | 5000 | 93.2 |
July 1996 | Good | Good | Good | Good | 4450 | 93.3 |
July 1994 | Good | Good | Good | Good | 3750 | 95.4 |
August 1992 | Good | Good | Very Good | Very Good | 3250 | 95.8 |
August 1990 | Good | Good | Very Good | Very Good | 2000 | 95.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 4,050 | 3,964 | 50 | 36 | 0 |
Steel Protective Coating | sq. ft. | 412,619 | 411,697 | 491 | 431 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 35,985 | 34,073 | 1,901 | 11 | 0 |
Substructure |
Reinforced Concrete Column | each | 20 | 19 | 0 | 1 | 0 |
Reinforced Concrete Abutment | linear ft. | 170 | 128 | 17 | 25 | 0 |
Concrete Protective Coating | sq. ft. | 420 | 420 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 415 | 415 | 0 | 0 | 0 |
Concrete Protective Coating | sq. ft. | 249 | 249 | 0 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 147 | 145 | 0 | 2 | 0 |
Assembly without Seal Joint | linear ft. | 67 | 67 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 69 | 34 | 27 | 8 | 0 |
Steel Protective Coating | sq. ft. | 78 | 55 | 23 | 0 | 0 |
Fixed Bearing | each | 24 | 18 | 6 | 0 | 0 |
Steel Protective Coating | sq. ft. | 36 | 18 | 18 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 1,052 | 1,052 | 0 | 0 | 0 |