Share:

US 50 over OHIO RIVER AND ROUTE 892

Map

Coordinates:
+39.27386, -81.64658
39°16'26" N, 81°38'48" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 50 over OHIO RIVER AND ROUTE 892
Structure number:00000000054A200
Location:3.00 MILE WEST OF WV 68
Purpose:Carries highway over highway, waterway, and railroad
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:878.7 ft. [267.8 m]
Total length:4009.1 ft. [1221.9 m]
Roadway width between curbs:96.1 ft. [29.3 m]
Deck width edge-to-edge:100.4 ft. [30.6 m]
Vertical clearance above deck:22.3 ft. [6.8 m]
Vertical clearance below bridge:75.5 ft. [23.0 m]
Owner:State Highway Agency [01]
Year built:2008
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Main span material:Steel [3]
Main span design:Arch - Thru [12]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Latex Concrete or similar additive [3]

Latest Available Inspection: April 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:13,175 [as of 2015]
Truck traffic:6% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:There are no noticeable or noteworthy deficiencies which affect the condition of the channel. [9]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:73.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$500,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2018FairSatisfactorySatisfactorySatisfactory1317573.0
April 2016FairGoodSatisfactorySatisfactory1630071.0
May 2014GoodGoodVery GoodVery Good1630071.0
May 2013GoodGoodVery GoodVery Good1630071.0
May 2012GoodGoodVery GoodVery Good1630071.0
May 2011GoodVery GoodVery GoodVery Good1630076.0
May 2010GoodVery GoodVery GoodVery Good1630071.0
August 2008GoodVery GoodVery GoodVery Good1630071.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Closed Web/Box Girderlinear ft.1,7751,59498830
Steel Protective Coatingsq. ft.79,50079,15715860125
Steel Girder/Beamlinear ft.28,64128,637400
Steel Protective Coatingsq. ft.891,400849,68141,709100
Steel Stringerlinear ft.7,9027,902000
Steel Protective Coatingsq. ft.84,40084,392800
Deck
Reinforced Concrete Decksq. ft.406,444406,31712700
Superstructure
Steel Archlinear ft.1,7601,7352500
Steel Protective Coatingsq. ft.146,000145,910343026
Steel Main Cablelinear ft.7,3807,380000
Steel Floor Beamlinear ft.1,5391,367130420
Steel Protective Coatingsq. ft.37,60037,446161308
Substructure
Reinforced Concrete Columneach2221100
Concrete Protective Coatingsq. ft.62,62161,80308180
Reinforced Concrete Pier Walllinear ft.2321894300
Concrete Protective Coatingsq. ft.10,5139,7850364364
Reinforced Concrete Abutmentlinear ft.237234300
Concrete Protective Coatingsq. ft.5,4955,495000
Other Material Abutmentlinear ft.577577000
Reinforced Concrete Pier Caplinear ft.1,1861,1315500
Concrete Protective Coatingsq. ft.48,77648,1981354394
Joints
Compression Jointlinear ft.101010100
Assembly with Sealeach202020200
Assembly without Seal Jointlinear ft.134134000
Bearings
Elastomeric Bearingeach258242790
Pot Bearingeach44000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.8,0098,008100
Reinforced Concrete Bridge Raillinear ft.12,01411,9734100
Concrete Protective Coatingsq. ft.46,48545,83565000
Deck
Reinforced Concrete Slabsq. ft.2,4302,424600