US 16 over Skull Creek
Map
Coordinates:
+43.91753, -104.3550443°55'03" N, 104°21'18" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 16 over Skull Creek |
Structure number: | CHR |
Location: | Upton - Newcastle |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 24.0 ft. [7.3 m] |
Total length: | 114.5 ft. [34.9 m] |
Roadway width between curbs: | 32.2 ft. [9.8 m] |
Deck width edge-to-edge: | 35.1 ft. [10.7 m] |
Owner: | State Highway Agency [01] |
Year built: | 1958 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 5 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Latex Concrete or similar additive [3] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 1,620 [as of 2017] |
Truck traffic: | 14% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 87.8 |
Recommended work: | Other structural work, including hydraulic replacements. [38] |
Estimated cost of work: | $83,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
August 2018 | Good | Good | Good | Good | 1620 | 87.8 |
February 2017 | Fair | Good | Satisfactory | Good | 3254 | 76.7 |
February 2015 | Good | Good | Good | Good | 3100 | 80.3 |
February 2013 | Good | Good | Good | Good | 1482 | 86.3 |
January 2011 | Poor | Critical | Fair | Good | 1486 | 68.9 |
January 2009 | Poor | Critical | Fair | Good | 1470 | 68.9 |
February 2007 | Poor | Serious | Fair | Good | 2140 | 65.4 |
February 2005 | Poor | Serious | Fair | Good | 1730 | 68.0 |
February 2003 | Poor | Poor | Satisfactory | Good | 1690 | 82.2 |
February 2001 | Poor | Poor | Satisfactory | Good | 1600 | 82.5 |
March 1999 | Fair | Satisfactory | Satisfactory | Good | 1550 | 83.8 |
February 1997 | Good | Good | Good | Good | 1590 | 83.7 |
March 1995 | Fair | Satisfactory | Good | Good | 1490 | 82.9 |
March 1993 | Good | Good | Good | Good | 1510 | 87.8 |
January 1992 | Good | Good | Good | Good | 1390 | 88.1 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Substructure |
Reinforced Concrete Column | each | 8 | 8 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 92 | 92 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 140 | 120 | 20 | 0 | 0 |
Bridge Rail |
Steel or Aluminum Bridge Rail | linear ft. | 229 | 229 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 733 | 733 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 4,037 | 3,477 | 560 | 0 | 0 |
Wearing Surfaces | sq. ft. | 4,037 | 3,517 | 520 | 0 | 0 |