Share:

NWP EB over EB Dillon Road

Map

Coordinates:
+39.95832, -105.09554
39°57'30" N, 105°05'44" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NWP EB over EB Dillon Road
Structure number:NWP-06.25A
Location:6.25 MI FROM I-25
Purpose:Carries highway over highway
Route classification:Other Principal Arterial (Urban) [14]
Tolls:Yes, on toll road [2]
Length of largest span:146.3 ft. [44.6 m]
Total length:315.0 ft. [96.0 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:41.0 ft. [12.5 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:58°
Owner:Local Toll Authority [32]
Year built:2002
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:15,000 [as of 2009]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:100.0
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017FairGoodSatisfactorySatisfactory15000100.0
June 2015FairGoodSatisfactorySatisfactory15000100.0
June 2013FairGoodSatisfactorySatisfactory15000100.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,5761,46710900
Concrete Protective Coatingsq. ft.1,5761,576000
Deck
Reinforced Concrete Decksq. ft.12,91912,79012900
Wearing Surfacessq. ft.11,97411,974000
Substructure
Reinforced Concrete Columneach1212000
Concrete Protective Coatingsq. ft.1212000
Reinforced Concrete Abutmentlinear ft.1551401500
Concrete Protective Coatingsq. ft.155155000
Reinforced Concrete Pier Caplinear ft.1551312400
Concrete Protective Coatingsq. ft.155155000
Joints
Strip Seal Jointlinear ft.155787700
Pourable Jointlinear ft.155155000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.630630000
Steel Protective Coatingsq. ft.630630000