Share:

RIVER RUN ROAD over E.FK.JARBIDGE RIVER

Map

Coordinates:
+42.02297, -115.36003
42°01'23" N, 115°21'36" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:RIVER RUN ROAD over E.FK.JARBIDGE RIVER
Structure number:000000000028198
Location:0.2S 0.1E MURPHY HOT SPR
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:59.1 ft. [18.0 m]
Total length:61.0 ft. [18.6 m]
Roadway width between curbs:21.0 ft. [6.4 m]
Deck width edge-to-edge:22.6 ft. [6.9 m]
Skew angle:12°
Owner:Other Local Agencies [25]
Year built:1922
Year reconstructed:2012
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 18 / H 20 [4]
Main span material:Steel [3]
Main span design:Truss - Thru [10]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:25 [as of 2016]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:58.4
Recommended work:Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Estimated cost of work:$575,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2018FairSatisfactoryFairFair2558.4
June 2016FairSatisfactoryFairFair2557.4
June 2014FairSatisfactoryFairFair2560.2
June 2012FairSatisfactoryFairFair2560.2

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Trusslinear ft.1220104180
Steel Protective Coatingsq. ft.2,69702,3043930
Steel Floor Beamlinear ft.23119613220
Steel Protective Coatingsq. ft.1,1431,141002
Steel Gusset Plateeach2230190
Steel Protective Coatingsq. ft.1381280010
Substructure
Reinforced Concrete Abutmentlinear ft.40040
Deck
Timber Decksq. ft.1,159997125370
Bearings
Movable Bearingeach40400
Steel Protective Coatingsq. ft.140000140