Share:

SB US 67 over FARMERS FORK

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SB US 67 over FARMERS FORK
Structure number:055008100000000
Old structure number:000055008143952 (from 1992 edition)
Location:1 MI S OF ILL 9
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:115.2 ft. [35.1 m]
Total length:118.4 ft. [36.1 m]
Roadway width between curbs:40.0 ft. [12.2 m]
Deck width edge-to-edge:43.3 ft. [13.2 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:2012
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:7,400 [as of 2015]
Truck traffic:12% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:There are no noticeable or noteworthy deficiencies which affect the condition of the channel. [9]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:76.7 tons [69.7 metric tons]
Inventory rating:58.9 tons [53.5 metric tons]
Sufficiency rating:97.2

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201697.2GoodGoodGoodGood-7400
November 201497.0GoodVery GoodVery GoodVery Good-7950
November 201297.0GoodExcellentExcellentExcellent-7950

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.711711000
Deck
Reinforced Concrete Decksq. ft.5,5175,517000
Substructure
Reinforced Concrete Abutmentlinear ft.122122000
Reinforced Concrete Pier Caplinear ft.123123000
Bridge Rail