CR1294, Taylor Rd. over Drainage Ditch from lake
Map
Coordinates:
+36.70222, -87.6000036°42'08" N, 87°35'60" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | CR1294, Taylor Rd. over Drainage Ditch from lake |
Structure number: | 024C00203N |
Location: | 0.1 mi. SE Jct Ky 107 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 13.1 ft. [4.0 m] |
Total length: | 26.9 ft. [8.2 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 25.9 ft. [7.9 m] |
Owner: | County Highway Agency [02] |
Year built: | 2011 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 2 |
Main spans material: | Concrete [1] |
Main spans design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: August 2017
Good/Fair/Poor Condition: | Good |
Status: | Posted for load [P] |
Average daily traffic: | 101 [as of 2012] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 69.7 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
August 2017 | Good | 7 out of 10 | 101 | 69.7 |
August 2015 | Good | 8 out of 10 | 101 | 69.7 |
August 2013 | Good | 8 out of 10 | 101 | 69.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Culvert |
Reinforced Concrete Culvert | linear ft. | 52 | 49 | 3 | 0 | 0 |