Share:

US 27 RAMP C NB over NS (CNO & TP) RR

Map

Coordinates:
+37.00194, -84.60833
37°00'07" N, 84°36'30" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 27 RAMP C NB over NS (CNO & TP) RR
Structure number:100B00118N
Location:269' N. OF JCT KY 1247
Purpose:Carries highway over railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:87.9 ft. [26.8 m]
Total length:195.5 ft. [59.6 m]
Roadway width between curbs:28.9 ft. [8.8 m]
Deck width edge-to-edge:32.2 ft. [9.8 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Skew angle:30°
Owner:State Highway Agency [01]
Year built:2008
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 22.5 / HS 25 [9]
Number of main spans:3
Main spans material:Prestressed concrete continuous [6]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:20,247 [as of 2017]
Truck traffic:6% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:77.1

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2018GoodGoodVery GoodGood2024777.1
July 2016GoodGoodVery GoodGood1993477.2
July 2014FairSatisfactoryVery GoodGood2063077.0
July 2012GoodGoodVery GoodGood2001277.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.766766000
Deck
Reinforced Concrete Decksq. ft.6,2555,99126400
Substructure
Reinforced Concrete Columneach44000
Reinforced Concrete Abutmentlinear ft.120116400
Reinforced Concrete Pier Caplinear ft.6666000
Bearings
Elastomeric Bearingeach1616000
Fixed Bearingeach88000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.100100000
Steel Protective Coatingsq. ft.160160000
Reinforced Concrete Bridge Raillinear ft.3902989200