Share:

PA TPK (I-76) over DEER CREEK

Map

Coordinates:
+40.57362, -79.86318
40°34'25" N, 79°51'47" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PA TPK (I-76) over DEER CREEK
Structure number:000000000002076
Location:INDIANOLA
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Tolls:Yes, on toll road [2]
Length of largest span:56.1 ft. [17.1 m]
Total length:56.1 ft. [17.1 m]
Owner:State Toll Authority [31]
Year built:1952
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Main span material:Concrete [1]
Main span design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: June 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:33,531 [as of 2004]
Truck traffic:19% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:70.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
June 2016Fair6 out of 103353170.0
June 2014Fair5 out of 103353159.0
June 2012Fair5 out of 103353159.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.201198300