Share:

T-615 CTY BR # 112 over LARRYS CREEK

Map

Coordinates:
+41.39832, -77.20008
41°23'54" N, 77°12'00" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:T-615 CTY BR # 112 over LARRYS CREEK
Structure number:000000000025065
Location:2.7 MI SW OF COGAN HOUSE
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:82.0 ft. [25.0 m]
Total length:94.2 ft. [28.7 m]
Roadway width between curbs:14.1 ft. [4.3 m]
Deck width edge-to-edge:15.4 ft. [4.7 m]
Vertical clearance above deck:8.9 ft. [2.7 m]
Owner:County Highway Agency [02]
Year built:1877
Year reconstructed:1998
Historic significance:Bridge is on the National Register of Historic Places [1]
Main span material:Wood or timber [7]
Main span design:Truss - Thru [10]
Deck type:Wood or Timber [8]
Wearing surface:Wood or Timber [7]

Latest Available Inspection: September 2015

Good/Fair/Poor Condition:Poor
Status:Posted for load [P]
Average daily traffic:10 [as of 2015]
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Poor [4 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Basically intolerable requiring high priority of corrrective action [3]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Meets minimum tolerable limits to be left in place as is [4]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Operating rating:8.0 tons [7.3 metric tons]
Inventory rating:5.9 tons [5.4 metric tons]
Sufficiency rating:15.4
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
September 201515.4PoorSatisfactoryPoorSatisfactorySD10
September 201315.4PoorSatisfactoryPoorSatisfactorySD10