Share:

S-3-18 over MILLER CREEK

Map

Coordinates:
+32.98408, -81.17928
32°59'03" N, 81°10'45" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:S-3-18 over MILLER CREEK
Structure number:000000000007059
Location:4MI NE FAIRFAX
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:15.1 ft. [4.6 m]
Total length:75.1 ft. [22.9 m]
Roadway width between curbs:31.5 ft. [9.6 m]
Deck width edge-to-edge:33.1 ft. [10.1 m]
Owner:State Highway Agency [01]
Year built:1978
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:M 13.5 / H 15 [2]
Number of main spans:5
Main spans material:Concrete [1]
Main spans design:Slab [01]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:225 [as of 2017]
Truck traffic:7% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:87.1

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
May 2017FairGoodGoodSatisfactory22587.1
May 2015FairGoodGoodFair22576.1
June 2013FairGoodGoodFair22576.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Timber Columneach3635001
Reinforced Concrete Pier Caplinear ft.204204000
Bridge Rail
Other Material Bridge Raillinear ft.150150000
Deck
Reinforced Concrete Slabsq. ft.2,5502,5242600
Wearing Surfacessq. ft.2,5502,550000