Share:

CR340(MORMON MIL) over DRAW

Map

Coordinates:
+30.60202, -98.08485
30°36'07" N, 98°05'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CR340(MORMON MIL) over DRAW
Structure number:140270C00340002
Location:2.0 MI NE OF US 281
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:7.9 ft. [2.4 m]
Total length:28.9 ft. [8.8 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:58.7 ft. [17.9 m]
Owner:Town or Township Highway Agency [03]
Year built:2010
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: January 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:200 [as of 2011]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:35.6 tons [32.4 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:90.4

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
January 201690.4Good7 out of 10-200
January 201498.9Good7 out of 10-200