COUNTY ROAD over WILLOW CREEK
Map
Coordinates:
+39.59794, -109.5722539°35'53" N, 109°34'20" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | COUNTY ROAD over WILLOW CREEK |
Structure number: | 047060C |
Location: | 13 MI.S.BUCK CYN.RD.JCT. |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 36.1 ft. [11.0 m] |
Total length: | 40.7 ft. [12.4 m] |
Roadway width between curbs: | 11.5 ft. [3.5 m] |
Deck width edge-to-edge: | 13.5 ft. [4.1 m] |
Owner: | County Highway Agency [02] |
Year built: | 1975 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Wood or Timber [7] |
Latest Available Inspection: April 2018
Good/Fair/Poor Condition: | Poor |
Status: | Posted for load [P] |
Average daily traffic: | 5 [as of 2010] |
Deck condition: | Poor [4 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Deck geometry appraisal: | Basically intolerable requiring high priority of corrrective action [3] |
Water adequacy appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection has failed. River control devices have been destroyed. Stream bed aggradation, degradation or lateral movement has changed the channel to now threaten the bridge and/or approach roadway. [3] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4] |
Sufficiency rating: | 24.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2018 | Poor | Poor | Fair | Fair | 5 | 24.0 |
April 2016 | Fair | Fair | Fair | Fair | 5 | 26.1 |
April 2014 | Fair | Fair | Fair | Fair | 5 | 20.7 |
April 2012 | Fair | Fair | Fair | Fair | 5 | 60.9 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 163 | 0 | 163 | 0 | 0 |
Substructure |
Other Material Abutment | linear ft. | 27 | 0 | 27 | 0 | 0 |
Deck |
Timber Deck | sq. ft. | 549 | 0 | 0 | 0 | 549 |