FR2182 over PINE RIVER
Map
Coordinates:
+45.83010, -88.9201045°49'48" N, 88°55'12" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FR2182 over PINE RIVER |
Structure number: | 091303000013222 |
Location: | 5.8 MI W OF JCT STH 55 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 40.0 ft. [12.2 m] |
Total length: | 40.0 ft. [12.2 m] |
Roadway width between curbs: | 24.0 ft. [7.3 m] |
Deck width edge-to-edge: | 25.9 ft. [7.9 m] |
Skew angle: | 30° |
Owner: | U.S. Forest Service [64] |
Year built: | 2009 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 22.5 / HS 25 [9] |
Main span material: | Wood or timber [7] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Wood or Timber [8] |
Wearing surface: | Wood or Timber [7] |
Latest Available Inspection: September 2016
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 50 |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Good [7 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 100.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2016 | Good | Good | Good | Good | 50 | 100.0 |
May 2014 | Good | Good | Good | Good | 50 | 100.0 |