Share:

Co Rd 3 / 119th S over Dry Creek No 2

Map

Coordinates:
+40.14225, -105.07418
40°08'32" N, 105°04'27" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:Co Rd 3 / 119th S over Dry Creek No 2
Structure number:BC-3-8.1-DR2
Location:0.9 Mi S of SH119
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:40.0 ft. [12.2 m]
Total length:44.0 ft. [13.4 m]
Roadway width between curbs:34.1 ft. [10.4 m]
Deck width edge-to-edge:36.4 ft. [11.1 m]
Owner:County Highway Agency [02]
Year built:2013
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Prestressed concrete [5]
Main span design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:1,815 [as of 2016]
Truck traffic:4% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:96.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2017GoodGoodGoodVery Good181596.7
February 2015GoodVery GoodVery GoodVery Good230098.3
July 2013GoodVery GoodVery GoodVery Good230098.3

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.2642442000
Substructure
Reinforced Concrete Abutmentlinear ft.7373000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.176017600
Steel Protective Coatingsq. ft.176000176
Deck
Reinforced Concrete Slabsq. ft.1,6061,5862000
Wearing Surfacessq. ft.1,4961,4530430