Share:

THOMPSON CREEK DR. over CREEK

Map

Coordinates:
+46.00843, -123.90130
46°00'30" N, 123°54'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:THOMPSON CREEK DR. over CREEK
Structure number:22351 000 00000
Location:.2 Ml S Lewis Clark RD
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:33.8 ft. [10.3 m]
Total length:33.8 ft. [10.3 m]
Roadway width between curbs:29.9 ft. [9.1 m]
Deck width edge-to-edge:29.9 ft. [9.1 m]
Owner:City or Municipal Highway Agency [04]
Year built:2005
Historic significance:Historical significance is not determinable at this time [4]
Main span material:Concrete continuous [2]
Main span design:Frame [07]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: April 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:472 [as of 2010]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:75.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
April 2017FairSatisfactoryVery GoodFair47275.9
April 2015FairSatisfactoryVery GoodFair47275.9
November 2014GoodVery GoodVery GoodVery Good47290.6

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Deck
Reinforced Concrete Decksq. ft.1,0101,0001000
Wearing Surfacessq. ft.842842000
Substructure
Reinforced Concrete Abutmentlinear ft.6060000
Reinforced Concrete Pile Cap/Footinglinear ft.3003000
Joints
Other Jointlinear ft.5252000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.6868000
Steel Protective Coatingsq. ft.300300000
Deck
Reinforced Concrete Slabsq. ft.1,01095545100