Share:

PR-66 over HERRERAS RIVER & CREEK

Map

Coordinates:
+18.36349, -65.85935
18°21'49" N, 65°51'34" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:PR-66 over HERRERAS RIVER & CREEK
Structure number:029752
Location:3.19 K. SW. OF RIO GRANDE
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Rural) [01]
Tolls:Yes, on toll road [2]
Length of largest span:126.3 ft. [38.5 m]
Total length:875.0 ft. [266.7 m]
Roadway width between curbs:40.7 ft. [12.4 m]
Deck width edge-to-edge:44.0 ft. [13.4 m]
Owner:State Highway Agency [01]
Year built:2013
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18+Mod / HS 20+Mod [6]
Number of main spans:7
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:25,000 [as of 2013]
Truck traffic:5% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:98.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
June 2017GoodVery GoodVery GoodVery Good2500098.0
May 2015GoodVery GoodVery GoodVery Good2500098.0
May 2013GoodVery GoodVery GoodVery Good2500098.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.5,2495,249000
Deck
Reinforced Concrete Decksq. ft.38,33038,330000
Substructure
Reinforced Concrete Columneach1212000
Reinforced Concrete Abutmentlinear ft.295295000
Reinforced Concrete Pier Caplinear ft.262262000
Joints
Compression Jointlinear ft.325325000
Bearings
Elastomeric Bearingeach8484000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.1,7521,752000