PR-66 WESTBOUND over CAMBALACHE RIVER
Map
Coordinates:
+18.37110, -66.5515118°22'16" N, 66°33'05" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | PR-66 WESTBOUND over CAMBALACHE RIVER |
Structure number: | 029872 |
Location: | PR-66, KM. 14.30 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Interstate (Rural) [01] |
Tolls: | Yes [1] |
Length of largest span: | 109.9 ft. [33.5 m] |
Total length: | 218.8 ft. [66.7 m] |
Roadway width between curbs: | 40.4 ft. [12.3 m] |
Deck width edge-to-edge: | 43.3 ft. [13.2 m] |
Owner: | State Highway Agency [01] |
Year built: | 2013 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18+Mod / HS 20+Mod [6] |
Number of main spans: | 2 |
Main spans material: | Prestressed concrete [5] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: May 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 22,863 [as of 2007] |
Truck traffic: | 5% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Very Good [8 out of 9] |
Structural appraisal: | Equal to present desirable criteria [8] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 98.0 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
May 2017 | Good | Good | Very Good | Very Good | 22863 | 98.0 |
May 2015 | Good | Good | Very Good | Very Good | 20000 | 98.0 |
May 2013 | Good | Good | Very Good | Very Good | 20000 | 98.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Girder/Beam | linear ft. | 1,316 | 1,316 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 8,837 | 8,837 | 0 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 2 | 2 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 167 | 167 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 43 | 43 | 0 | 0 | 0 |
Joints |
Compression Joint | linear ft. | 131 | 118 | 13 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 436 | 436 | 0 | 0 | 0 |