Broadlands Drive over Local Drainage
Map
Coordinates:
+39.94797, -105.0460639°56'53" N, 105°02'46" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | Broadlands Drive over Local Drainage |
Structure number: | BFD-BRLND-LONG |
Location: | 0.3 Mi N of 136th Ave |
Purpose: | Carries highway and pedestrian walkway over waterway |
Route classification: | Local (Urban) [19] |
Length of largest span: | 12.1 ft. [3.7 m] |
Total length: | 25.3 ft. [7.7 m] |
Roadway width between curbs: | 28.2 ft. [8.6 m] |
Deck width edge-to-edge: | 59.7 ft. [18.2 m] |
Skew angle: | 34° |
Owner: | City or Municipal Highway Agency [04] |
Year built: | 1997 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Main span material: | Concrete [1] |
Main span design: | Culvert [19] |
Deck type: | Not applicable [N] |
Latest Available Inspection: January 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 890 [as of 2012] |
Truck traffic: | 10% of total traffic |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Better than present minimum criteria [7] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 88.4 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
January 2017 | Good | 7 out of 10 | 890 | 88.4 |
January 2015 | Good | 7 out of 10 | 890 | 88.4 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Culvert |
Reinforced Concrete Culvert | linear ft. | 144 | 134 | 10 | 0 | 0 |