Share:

County Road 10 over South Fork White River

Map

Coordinates:
+39.92194, -107.55167
39°55'19" N, 107°33'06" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:County Road 10 over South Fork White River
Structure number:RIOB-010-07.27A
Location:7.27 Mi E of Co Rd 8
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:88.9 ft. [27.1 m]
Total length:95.1 ft. [29.0 m]
Roadway width between curbs:32.2 ft. [9.8 m]
Deck width edge-to-edge:35.1 ft. [10.7 m]
Skew angle:20°
Owner:County Highway Agency [02]
Year built:2015
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Main span material:Prestressed concrete [5]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: September 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:99 [as of 2012]
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present desirable criteria [8]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:94.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
September 2018GoodGoodGoodGood9994.3
September 2016GoodGoodGoodGood9994.3
September 2015GoodVery GoodVery GoodVery Good9994.3

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.381379200
Deck
Reinforced Concrete Decksq. ft.3,3323,2795300
Substructure
Reinforced Concrete Abutmentlinear ft.7170100
Joints
Pourable Jointlinear ft.7171000
Bearings
Elastomeric Bearingeach88000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.190190000
Steel Protective Coatingsq. ft.190190000