Share:

SH 36 over MINK CREEK

Map

Coordinates:
+42.24222, -111.71000
42°14'32" N, 111°42'36" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SH 36 over MINK CREEK
Structure number:000000000014086
Location:8.6 E. SH 34/SH 36 JCT
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:51.8 ft. [15.8 m]
Total length:51.8 ft. [15.8 m]
Roadway width between curbs:33.1 ft. [10.1 m]
Deck width edge-to-edge:36.1 ft. [11.0 m]
Owner:State Highway Agency [01]
Year built:2015
Historic significance:Historical significance is not determinable at this time [4]
Main span material:Prestressed concrete [5]
Main span design:Slab [01]
Deck type:Concrete Precast Panels [2]
Wearing surface:Bituminous [6]

Latest Available Inspection: November 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:300 [as of 2015]
Truck traffic:16% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:There are no noticeable or noteworthy deficiencies which affect the condition of the channel. [9]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:97.9

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
November 2017GoodVery GoodVery GoodGood30097.9
November 2015GoodExcellentExcellentExcellent55096.8

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Abutmentlinear ft.112107500
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.110110000
Steel Protective Coatingsq. ft.482482000
Deck
Reinforced Concrete Slabsq. ft.1,9911,991000
Wearing Surfacessq. ft.1,8151,7516040
Concrete Protective Coatingsq. ft.1,8151,815000