Share:

BUFFINGTON HRBR DR over CSX/NS RR

Map

Coordinates:
+41.63651, -87.42214
41°38'11" N, 87°25'20" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:BUFFINGTON HRBR DR over CSX/NS RR
Structure number:4500230
Location:00.66 E. of SR 912
Purpose:Carries highway over railroad
Route classification:Collector (Urban) [17]
Length of largest span:159.1 ft. [48.5 m]
Total length:265.8 ft. [81.0 m]
Roadway width between curbs:26.9 ft. [8.2 m]
Deck width edge-to-edge:38.4 ft. [11.7 m]
Vertical clearance below bridge:23.0 ft. [7.0 m]
Skew angle:99°
Owner:City or Municipal Highway Agency [04]
Year built:2015
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:7,880 [as of 2012]
Truck traffic:3% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Excellent [9 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:80.1

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
August 2016GoodVery GoodExcellentVery Good788080.1
August 2015GoodVery GoodExcellentGood788080.1