Share:

TH 43 over STREETS; MISS RVR; RR

Map

Coordinates:
+44.05756, -91.63972
44°03'27" N, 91°38'23" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:TH 43 over STREETS; MISS RVR; RR
Structure number:85851
Location:2.8 MI N OF JCT TH 61
Purpose:Carries highway and pedestrian walkway over highway, waterway, and railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:450.2 ft. [137.2 m]
Total length:2295.1 ft. [699.5 m]
Roadway width between curbs:34.1 ft. [10.4 m]
Deck width edge-to-edge:50.2 ft. [15.3 m]
Vertical clearance below bridge:62.3 ft. [19.0 m]
Owner:State Highway Agency [01]
Year built:2014
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:10,500 [as of 2017]
Deck condition:Very Good [8 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge is scour critical; bridge foundations determined to be unstable. [3]
Sufficiency rating:80.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2018GoodVery GoodGoodGood1050080.0
October 2016GoodVery GoodVery GoodExcellent1050080.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Closed Web/Box Girderlinear ft.934929500
Prestressed Concrete Girder/Beamlinear ft.7,0287,028000
Deck
Reinforced Concrete Decksq. ft.59,14859,1074100
Wearing Surfacessq. ft.39,98139,9255600
Prestressed Concrete Top Flangesq. ft.47,84247,7925000
Wearing Surfacessq. ft.31,73031,6854500
Substructure
Reinforced Concrete Columneach3636000
Reinforced Concrete Pier Walllinear ft.1751601500
Reinforced Concrete Abutmentlinear ft.186184200
Reinforced Concrete Pile Cap/Footinglinear ft.757757000
Joints
Strip Seal Jointlinear ft.4848000
Pourable Jointlinear ft.340340000
Assembly with Sealeach144426960
Bearings
Elastomeric Bearingeach8080000
Movable Bearingeach1210200
Fixed Bearingeach4847100
Disk Bearingeach40400
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.6,8396,839000
Steel Protective Coatingsq. ft.20,74319,706001,037
Reinforced Concrete Bridge Raillinear ft.6,9303,4643,46510
Deck
Reinforced Concrete Slabsq. ft.9,3219,3051600
Wearing Surfacessq. ft.6,3006,291900